Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is difference between assayand potency

Answer Posted / ala

potency meaning the bio activity for the API
assay is the quantitative for the api

Is This Answer Correct ?    6 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

which one is better separation in high pressure liquide chromatogram orlowpressure chromato gram in hplc

2210


Why acetonitrile and water are used as extraction solvent when analysis melamine? I thought they are miscible and won't be able to separate...

1750


why sre you used Potassium hydrogen phthalate in standarisation of 1N NaOH and 0.1 N Perchloric Acid?

9883


We use Potassium Dichromate solution for the calibration of UV-Visible Spectrophotometer in UV region. My question is to calibrate visible region which solution could be used in photometric accuracy

1960


How they found 1mL of K.F reagent is equivalent to 5mg of water and if we change the composition of K.F reagent, is it can neutralize more amount of water?

1827


what is difference in ods I ods II is this is realy from sorbent / packing characteristics or from other means

2008


If change in specification which parameter require to do for validation? if change in chromtographic condition then which parameter? if api change then which parameter? if change composition then which parameter? if old method not work out then whicj parameter? if additional one impurity added then which parameter of validation require to do on above each conditions? elaborate separately

901


if instrument calibration fails then what require to do?

1017


what is difference between UV - VISIBLE MODEL NO like 1600,1601,1700 etc ? plz explain me

2723


what is classification of elemental impurities? what is risk assement in elemental impurities?

806


What is related substance by HPLC impurity limits as per USP?

1153


for which product require to do content uniformity? what is limit of cu?

867


what is mean by dissolution hydrodynamics?

882


if peak get problamatic then what require to do?

858


how pda detector works over uv?

777