Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

reasons for negative peaks in chromatography

Answer Posted / ramakrishna,micro labs

Based on mobile phase negative peaks we observed,for ex: the mobile phase having TEA,Acetic acid or OPA (those all r used for mobile phase pH adjustment) .that type of chemicals will show negative response in HPLC

Is This Answer Correct ?    1 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1579


in DMF having extra impurities and in api COA also having extra imp than USP or BP product then how require to proceed?

805


how pda detector works over uv?

724


what is third integration

1961


1)What's the meaning of Absorption,give a example. 2)What's the meaning of Adsorption,give a example. 2)what is the difference between Absorption and Adsorption.

2870


how require to fix the linearity and accuracy cincentration range?

1646


what is the principle involved in turbidometry and nephelometry ?

4151


How can I develope method of dissolution by HPLC OR UV

2391


Why six unit used for precision?

1320


in gas chromatography what is the difference between gas flow rate and average linear velocity ?

2578


what is %labelled amount in content uniformity of dosage unit and its calculation?

5196


WHY given much noise PDA dector then VWD Dector

2076


What is similarity factor?

1177


process of Diclofenac sodium,IP.

2185


in monograph 7 imp are there but in vendor showing 5 imp do not req to include 2 imp for that what will be justification?

709