Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

today i am doing calibration of HPLC. when i inject the
blank it was going on -ve.(bleow then zero) why?

Answer Posted / sudheer kumar m

may be mobile phase was not stable in that particular
method. so condition the column with mobile phase and re inject.

Is This Answer Correct ?    2 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is difference between UV - VISIBLE MODEL NO like 1600,1601,1700 etc ? plz explain me

2736


what parameters we will consider while developing a HPLC method and how we confirm our HPLC method is valid?

3750


how to select short coloum and long coloumn for new molecule

2528


we are performed SOR for a particular product the limit is -6 to -10.We face particular bathes it is not meeting the specification.we performed diffrent instrument diffrent analyst we are getting diffrent diffrent results.solvent is dimethyl sulfoxide what could be the reasion

1921


If change in specification which parameter require to do for validation? if change in chromtographic condition then which parameter? if api change then which parameter? if change composition then which parameter? if old method not work out then whicj parameter? if additional one impurity added then which parameter of validation require to do on above each conditions? elaborate separately

910


From where require to take the RLD sample?

806


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3585


Please tell me about the pH of Polycaboxylic ether is it in the 5-6 range ever or more than 6

2655


for heavy metal test lead used in which form pure form or any other form for preparation of lead standard sol

6144


how you start the solubility study?

864


What are the primary considerations in extractables and Leachables ?

2320


in which situation require to take incident in validation?

1783


A ha tc is actual defination of retention time?

1664


How to do regeneration of Metacarb Pb plus column?

2611


How to choose the which salt is suitable for mobilephase

3304