Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is meaning of audit trail in hplc

Answer Posted / s jagadeesh chandra

Audit trail is regulatory requirement.Pass word procted.

Audit trails will gives us accountubility.The auditor will
clearly identifies what had happened by observing audit
trails.

Audit trail will keeps a record of all the changes we do ie
deleting,correcting,editing the data.Software log ins and
log outs.System shut downs and start ups.Method changes,
errors occured etc.

Audit trails will not be attributed to hplc only.It can be
used for other instruments also like gc,ir,uv etc... if the
software we are using permits.

we can say more about audit trails but i explained briefly.

Is This Answer Correct ?    41 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Explain the relations between number of carbon atoms in alkanes and retention time ?

2072


Loss of linearity in tkn analysis, possible reasons?

1255


what is lod and loq ?,why use k2cr2o7 , kcl h2so4 in uv calibration ?,why use benzophenone & caffene acetone in hplc calibration ?,what is leading peak in hplc ?why we do the calibration of limit of stry light in hplc & uv ?

3620


WHICH STANDARD WE USE IN SILICA ANALYSIS IN SILICA-GEL METHOD FOR SOLID SAMPLE

2075


How we choose the mobile phase for method development.?

1161


WHY given much noise PDA dector then VWD Dector

2048


Which is the highly polar and highly non polar column in HPLC?

2239


in monograph 7 imp are there but in vendor showing 5 imp do not req to include 2 imp for that what will be justification?

665


in each media we require to use SLS? how to proceed?

722


some product having water content method with pyridine and ethylene glycol mixture instead of methanol? how they are selecting and methanol is not suitable solvent how ?

2598


Basic principle of ESI?

2096


what is classification of elemental impurities? what is risk assement in elemental impurities?

706


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1546


please explian me about area normalisation method,diluted standard method,impurity vs impurity and which one has to be selected in method development

1575


We use Potassium Dichromate solution for the calibration of UV-Visible Spectrophotometer in UV region. My question is to calibrate visible region which solution could be used in photometric accuracy

1832