Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Is sonication essential in solubility testing of a drug
substance?

Answer Posted / pharmainterview

There is no guideline which specifies the sonication
required or not for solubility. So some people prefer to
sonicate and other not. You can't say which one is wright
because you have no evidenced guideline.

Regards
pharmainterviewquestions.blogspot.in

Is This Answer Correct ?    8 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1600


Why we used in n-butyl acetate water content terminology while in ethyl acetate we used moisture content terminology?

1865


Why do we use KMnO4 in the test of control of obsorbance ? and why do we take specific quantity i.e 57-63mg?

2833


why require to add enzymes in capsules dissolution only? is it require to tablet also?

680


can i use hplc detector to uplc and why?

2293


How to fix the sample conc. in Related substances test by HPLC?

1099


what is the procedure for cleaning of lenses of hatr accesory of ftir instrument?

2296


UV and PDA detector, which have less signal to noise ratio?

1137


In BP2013, Loperamid HCl monograph. Assay by titration with 0.1N sodium hydroxide using hydrocloric acid 0.01N and reading the volume added between the 2 points of inflexion. I have a question that if the diluent solvent is ethanol is certainly consumed a amount of volume of titrant, so this volume must be eliminated on the result calculation or not apart from first point which is subtracted above.

3129


How will u perform degradation study in detectors other thann PDA in HPLC Methodology

2549


what is mean by covalidation

785


In rs method development when we are going area normalization method to dilute standard method?

1528


WHAT IS THE PARAMETER FOR THE SELECTION OF MOBILE PHASE IN HPLC?

1193


Is it nessesary all multimedia dissolution require descriminatory?

800


if you have given a blank water how you analyse by general analytical techniques?

2033