Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

From where 16 or 5.545 is derived in theoretical plates
calculation formula by USP or JP/BP/DAB and what is meaning
of this coefficient and impact in calculation ?

Answer Posted / sp goswami

formula for N = 16*(t/w)2
but whats the meanin of 16 and from whr its coming ?

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

In HPLC (Waters) software Empower1,2 &3 what is the updation for each version

2958


How to compare XRD graphs against standard and carry polymorpism study of API's by powder XRD method?

3818


If we have 5 strength which is not dose proportinate and excipients also diffrent in each strength then how we can proceed for Force degradation? and excipient are same but not dose propotinate the how FD?

757


could negative ions be produced by bombardment process in mass spectrometry?

1720


why cone formation during dissolution?

730


how much mass should be there in volumetric flask while in preparation of sample for assay? 

2512


what type of question will ask in the interview of lab chemist.

3261


on the basis of bcs class how to proceed the solubility?

699


How would you decide dissolution medium for NCE compound of class I drug

2192


What is column in chromatography?

2190


is it necessary to do HPLC calibration at wavelength 315nm if we are doing analysis at this wavelangth

2105


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1546


identification is for unknown? qualification for known? reporting for LOQ?

665


AT WHAT CONDITIONS WILL YOU ANALYSE A SAMPLE,WHICH ARE PRESERVED AT OTHER THAN THE AMBIENT CONDITIONS?(ie COLD STORAGE SAMPLES BELOW 20* CENTIGRADE?

2013


how to get accurate result for Residue on evaporation in purified water

1579