Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the purpose & importance of using the
polystyrene film in ir calibration?

Answer Posted / m balaram naidu

POLYSTARENE FILM MADE BY POLYMER OF STYRENE. IT IS HIGHLY
DURABILITY AT ANY TEMPARECTURE.
POLYSTARENE FILM GIVES SHARP PEAKS WHICH COVER WHOLE IR
RESION.

Is This Answer Correct ?    9 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How do we fix the sample concentaryion in hplc method development. What is the basis?

1195


What is Band broading effect explain

1872


what is the extinction coefficient for Indomethacin or at 319nm wave length.

4059


What is viod volume and peak purity in HPLC?

2874


please explian me about area normalisation method,diluted standard method,impurity vs impurity and which one has to be selected in method development

1619


What is the principle of HPLC, GC, LCMS, GCMS,LC QQQ, GC QQQ, LC Q TOF and GC Q TOF. What are the applications and Specificity?

8855


in api coa contains only process impurities and in product coa contains degradation impurities?

694


what is difference between UV - VISIBLE MODEL NO like 1600,1601,1700 etc ? plz explain me

2665


How do we fix the sample concentaryion in hplc method development?

1130


WHAT IS THE PARAMETER FOR THE SELECTION OF MOBILE PHASE IN HPLC?

1181


what type of question will ask in the interview of lab chemist.

3306


why multimedia dissolution require to do?

808


from where i get mortar pastle for glass bottle crush? it's required for testing of it?

2258


A ha tc is actual defination of retention time?

1612


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards