Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

As per OOT for any product what is calculation and how to
invetigate the OOT

Answer Posted / s jagadeesh chandra

This is only a briefe answer.

OOT means out of trend.

Definition:

In case of routene analysis any result of quantitative
chemical test that do not fall with in the defined band in
comparison to a specification.

Investigation:

Investigation procedure is same as that of OOS(Out of
specification).

OOt result in qc laboratory
.
Report with in 24 hours to qa&supervisor.
.
phase I laboratory investigation is carried out.
.
If any laboratory error is identified then it is termed as
assiagnable cause(ie system problem identified,sample
preparation,dilution in correct,improper transfer of
solvent,analyst etc etc...).There are many check points are
there to investigate.The investigator will go through the
check points.
.
After assiagnable cause identification corrective and
preventive action will be taken,and order for re testing
the original sample or another on same or another equipment
(if system performance is suspected).The person other than
who obtain the initial results should re test the
sample.After re testing results are to be evaluated and
conclude the investigation.

Re testing plan:2 sample preparetions to be done and analyse

Different different OOT limits are there for different
different tests.

For more details mail me.

Is This Answer Correct ?    16 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the structure of DOWEX-50

5452


in which situation require to take incident in validation?

1651


how can I make the copper get white bye any salt or acit?

2146


In the HPLC Calibration done wavelength accuracy done between 200nm-280nm .but not done remaining 300-400nm not done ?

858


AT WHAT CONDITIONS WILL YOU ANALYSE A SAMPLE,WHICH ARE PRESERVED AT OTHER THAN THE AMBIENT CONDITIONS?(ie COLD STORAGE SAMPLES BELOW 20* CENTIGRADE?

2013


How much is the standard area for glc analysis

2210


which one is better separation in high pressure liquide chromatogram orlowpressure chromato gram in hplc

2117


[3/30, 13:29] Manoj P Venkatpurwar: How hplc column selection according to structure? How mobile phase buffer selection on molecule structure?

708


What is Band broading effect explain

1827


if you have given a blank water how you analyse by general analytical techniques?

1975


what is %labelled amount in content uniformity of dosage unit and its calculation?

5137


What is delay volume?

1327


How do we fix the sample concentaryion in hplc method development. What is the basis?

1140


why require the ph, buffer during hplc mobile phase?

816


What is dose dumping? why require to do?

873