Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is Spliit and Splitless in Gas Chromatography nad How
does it work?

Answer Posted / k.vineel kumar

Split liner is that in which it takes only i part from the
injection volume and dicards the remaining 4 parts through
vent outside if the split ratio is 1:5


Splitless is that in which if 1µl is the injection volume
it takes full of it and vent is not present in splitless
liner.

So ultimately the responses will be high in Splitless than
in split

Is This Answer Correct ?    3 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How require to develop GC method? how to select diluent, GAS, column selection and other chromatographic conditions?

715


What is gelatinization?

1606


What is the purpose of octyl silane columns?

4280


we are performed SOR for a particular product the limit is -6 to -10.We face particular bathes it is not meeting the specification.we performed diffrent instrument diffrent analyst we are getting diffrent diffrent results.solvent is dimethyl sulfoxide what could be the reasion

1850


what is definition of validation? which components are followed give detail?

2339


give clarity of linearity and range in method validation

2405


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3526


Which parameter require to do for analytical method equivalency?

762


all types of questions asked at the cipla interview

4668


how require to set assay concentration for standard and sample?

909


How we performed the force degradation for drug substance, is any specific guideline is available for each parameter(Acidic, basic, oxidation,heat)? what conditions you mentained for above parameters.

2297


why we use a particular hplc column for a particular compound give reasons?please

2733


what is the principle involved in turbidometry and nephelometry ?

4152


How do we fix the sample concentaryion in hplc method development. What is the basis?

1189


What is the requirement for brazil in the analytical method vslidation comparr to ich?