Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why we are using the methanol in Kf titration?

Answer Posted / radheraman singh

Selection of methanol in Kf having following reason.
1 prevent the side reaction between pyridine and SO2.
2 Many compound are soluble in MeOH.
3 MeOH not absorbed moisture and having very less water content.

Is This Answer Correct ?    30 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3540


how much mass should be there in volumetric flask while in preparation of sample for assay? 

2577


Many times I don't got a caffeine peak in calibration of hplc using guard column ❓

1819


in which situation require to use paddle and basket?

737


What is delay volume?

1392


Ratio of Water and Acetonitrile(diluent) is not recommended to use in cleaning method validation,why?

2963


What is split ratio in Gc? Splitless? how requirr to select?

891


about method developement in hplc

1714


What is mean by PDR?

943


what is lod and loq ?,why use k2cr2o7 , kcl h2so4 in uv calibration ?,why use benzophenone & caffene acetone in hplc calibration ?,what is leading peak in hplc ?why we do the calibration of limit of stry light in hplc & uv ?

3667


In IR spectra, generally a molecule vibrates without apply emr or ir light?

1977


WHAT IS THE CRITERIA FOR SELECTION OF TIME OF DISSOLUTION AND THE MEDIUM OF DISSOLUTION?

2576


for heavy metal test lead used in which form pure form or any other form for preparation of lead standard sol

6070


For limit test of heavy metals in BP, Method C require that the substance is ignited at a temperature not exceeding 800 °C. Why confines such the temperature?

4069


WHY pKa value is more important than pH value of the mobile phase in HPLC?

1768