Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why we are using only KBr in IR spectrometer why not KCl

Answer Posted / ramalaxmi ch

KBR can not absorbance in IR region. and it is a primary standard.
KBR does not catch the moisture easy better than KCL
KBR STABLE also

Is This Answer Correct ?    10 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

In rs method development when we are going area normalization method to dilute standard method?

1520


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1595


what you do when compound having dwel wavelength?

747


A ha tc is actual defination of retention time?

1617


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3538


What is dose dumping? why require to do?

947


Please give idea about method development for cleaning method and how maco level establish

747


How to start the dissolution development for unknown tab?

1679


can we use the same detector in HPLC as well GC and what could be the differences we can find in the final chromato graph in any aspects?

2178


how the compound separate in coulunm,explain

2529


which situation gc hs and gc als require to use?

783


inhouse product is in capsule form in combination and RLD is in tablet form then can we proceed for multimedia CDP? in inhouse capsule product disso is paddle with sinker in release media is there then RLD product in tablet form then with same as paddle with sinker we can proceed n.a.?

715


[3/30, 13:29] Manoj P Venkatpurwar: How hplc column selection according to structure? How mobile phase buffer selection on molecule structure?

782


What is a difference between potency and purity?

1219


Loss of linearity in tkn analysis, possible reasons?

1315