what is the difference of use of LOD test and Karl Fischer
titra.?
Answer Posted / suresh
in kf test we can determine water content when compound has
below 60 degree melting point.
In LOSS ON DRYING we can determine organic volatile
impurities& water content of drug substance.
| Is This Answer Correct ? | 5 Yes | 1 No |
Post New Answer View All Answers
what is the extinction coefficient for Indomethacin or at 319nm wave length.
acceptance criteria for lod & loq by standard deviation of response and slope??
when we talk about change in entropy we consider total entropy means of surround +entropy of system but when we talk about change in Gibss free energy we consider entropy of system.explain with reason.
For titration in anhydrous media with perchloric acide, if lack of titrator, Which indicator is been used for replacement. How calculate pH of test solution to choose suitable indicator?
how pda detector works over uv?
How can the GC or HPLC method is selected to determine the impurity profile in drug product?
what is the acceptance criteria for enteric coated tablets in 0.1n hcl validation in each parameter?
In rs method development when we are going area normalization method to dilute standard method?
What is third generation HPLC Columns?
How will u perform degradation study in detectors other thann PDA in HPLC Methodology
How we choose the mobile phase for method development.?
what type of question will ask in the interview of lab chemist.
for inorganic molecules require to do RS, Assay and disso?
Why only hydroxy naphthol blue indicator is used for standardisation of 0.05M EDTA solution instead of solochrome Black T or Euriochrome Black T indicator which is used for all sample analysis with 0.05M EDTA solution?