Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the difference between Paddle and Basket Why we are
using Basket or paddle in dissolution.

Answer Posted / dhiraj kumar

Generally we are using basket in those tablets in which HPMC is using as a binder because if HPME will come to contract with water then it will show sticky correcter and the tablet in which HPMC is used as a binder will get swell and stick with vessel and drug is not release because tablet will not move properly but in basket tablet is in the center of the vessel and so drug will release continue.

Is This Answer Correct ?    52 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

in OSD forms require to use gas chromatography?

834


What is intact assay method development.....?

2659


WHAT IS THE PARAMETER FOR THE SELECTION OF MOBILE PHASE IN HPLC?

1183


How can the GC or HPLC method is selected to determine the impurity profile in drug product?

7594


What is the principle of HPLC, GC, LCMS, GCMS,LC QQQ, GC QQQ, LC Q TOF and GC Q TOF. What are the applications and Specificity?

8860


How do we fix the sample concentaryion in hplc method development?

1136


Why we use potassium dichromate in uv calibration Exact reason behind it??

1255


all types of questions asked at the cipla interview

4676


What is the difference between Discriminating media and DPDM(Dissolution Profile with Different Media)

7540


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3538


EXPLAIN THE CALCULATION PART OF AN KF TITRATOR CALIBRATION WITH SUITABLE EXAMPLE

2634


what is mean by ambient temperature?

914


what is the origin to prepare standard operating procedure

2320


what is different when impergnated silica plates are used in separation of azo dyes using column chromatography?

2024


A ha tc is actual defination of retention time?

1617