Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what r the parts calibrated in gc

Answer Posted / s v ramesh

1. OVEN TEMPERATURE

2. HSS SENSITIVITY WITH USING ETHANOL OR IPA

3. CAPILLARY SENSITIVITY OF FID USING FID SAMPLE

4. DETECTOR LINEARITY.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the difference between spectro meter and spectro photo meter?

11345


2. Two grams of Benzoic acid are dissolved in 200 ml of water and extracted with 200 ml of diethyl ether. The distribution coefficient of benzoic acid is 100, and its dissociation constant is 6.5 10-5. Calculate the distribution ratio (D) of benzoic acid at pH 2, 5, and 6. 3. Calculate D at pH 2 to 10 (1 unit apart) in the above problem, and plot D versus pH.

2171


For limit test of heavy metals in BP, Method C require that the substance is ignited at a temperature not exceeding 800 °C. Why confines such the temperature?

4003


From where require to take the RLD sample?

706


please explian me about area normalisation method,diluted standard method,impurity vs impurity and which one has to be selected in method development

1575


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3487


what is the different in Total ash, sulphated ash, acid insoluble ash, alcoholic or non alcoholic ash?

9926


what is difference in ods I ods II is this is realy from sorbent / packing characteristics or from other means

1922


if rsd failed then what require to do?

763


Ph meter can show more than 14 ph reading? Why ph range in between 1 to 14 only?

688


how you start the solubility study?

767


what is mean by ambient temperature?

863


what is %labelled amount in content uniformity of dosage unit and its calculation?

5137


How you develop a method in HPLC?

2562


why we use a particular hplc column for a particular compound give reasons?please

2684