Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why we are using the methanol in Kf titration?

Answer Posted / venkataramireddy.bh

ALL PHARMACEUTIAL COMPOUNDS ARE EASILY SOLUBLE IN
METHANOL,THE SELECTION OF METHANOLIS IT SHOULD CONTAIN LESS
WATERCONTENT







from vivimed

Is This Answer Correct ?    9 Yes 12 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

when we talk about change in entropy we consider total entropy means of surround +entropy of system but when we talk about change in Gibss free energy we consider entropy of system.explain with reason.

2028


How to fix the sample conc. in Related substances test by HPLC?

1068


Why only hydroxy naphthol blue indicator is used for standardisation of 0.05M EDTA solution instead of solochrome Black T or Euriochrome Black T indicator which is used for all sample analysis with 0.05M EDTA solution?

2702


What is split ratio in Gc? Splitless? how requirr to select?

863


in monograph 7 imp are there but in vendor showing 5 imp do not req to include 2 imp for that what will be justification?

710


Why we use potassium dichromate in uv calibration Exact reason behind it??

1240


how you establish the LOQ?

765


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1580


For titration in anhydrous media with perchloric acide, if lack of titrator, Which indicator is been used for replacement. How calculate pH of test solution to choose suitable indicator?

2300


1)What's the meaning of Absorption,give a example. 2)What's the meaning of Adsorption,give a example. 2)what is the difference between Absorption and Adsorption.

2872


why we are using hexane in calibration of number of drop per mL

1717


What is the Formula for coreletion coefficient in plhplc calibration

1806


for inorganic molecules require to do RS, Assay and disso?

721


how the compound separate in coulunm,explain

2508


what is difference between UV - VISIBLE MODEL NO like 1600,1601,1700 etc ? plz explain me

2657