Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the peak purity concept?

Answer Posted / raghavaiah mandalapu

A technique is described whereby the purity of an HPLC peak
can be determined by using electrospray liquid
chromatography-electrospray ionization mass spectrometry.
Electrospray mass spectra acquired across an HPLC peak are
summed and examined for co-eluting impurities. The mass
spectrometer is set up to produce solely cationised
molecules and background noise is minimized so that minor
coeluting impurities can be observed down to a level of
<0.1% of the major component. This method offers advantages
over using diode-array UV detection (LC-DAD) for the
determination of HPLC peak purity, namely components with
similar UV spectra can be distinguished, the molecular mass
of the impurity can be determined and structural data can
be obtained by using tandem mass spectrometry (MS-MS). The
effectiveness of the technique is demonstrated with drug
substances of pharmaceutical interest which have been
chromatographed on an HPLC system designed to intentionally
co-elute a number of impurity standards with these
compounds.

Is This Answer Correct ?    5 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

on saturation solubility study data how we can find out the bcs class of drug?

903


Why sodium hydroxide used for maintain pH of phosphate buffer

2415


How to fix the sample conc. in Related substances test by HPLC?

1099


what is difference between UV - VISIBLE MODEL NO like 1600,1601,1700 etc ? plz explain me

2685


How to determine the EDTA content by potentiometry titration in Ceftriaxine sodium

2548


for inorganic molecules require to do RS, Assay and disso?

734


in DMF having extra impurities and in api COA also having extra imp than USP or BP product then how require to proceed?

839


Please give idea about method development for cleaning method and how maco level establish

752


what is partion and column chromatography

2393


Why sometime potassium ortho phosphate mix with acetone use for sample preparation for hplc

1471


2. Two grams of Benzoic acid are dissolved in 200 ml of water and extracted with 200 ml of diethyl ether. The distribution coefficient of benzoic acid is 100, and its dissociation constant is 6.5 10-5. Calculate the distribution ratio (D) of benzoic acid at pH 2, 5, and 6. 3. Calculate D at pH 2 to 10 (1 unit apart) in the above problem, and plot D versus pH.

2224


How can we calculate offset value pH measurment

1511


Why we check moisture,ash & AIA in product

1886


analytical method validation require to with respect to release specification or shelf life specification?

796


is it necessary to do HPLC calibration at wavelength 315nm if we are doing analysis at this wavelangth

2177