Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how to pepare 6.8 pH phosphate buffer

Answer Posted / swathi

Take 0.01M KH2PO4 (1.36g) in 1000mL water and sonicate it
properly and check the pH and adjust the pH to 6.8 by using
Orthophosphoric acid if pH is more than 6.8,or use KOH or
NaOh if pH is less than 6.8

Is This Answer Correct ?    18 Yes 8 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the extinction coefficient for Indomethacin or at 319nm wave length.

4125


why we are using benzene, anyline in acetic anhdride assay titration method?

2168


what is lod and loq ?,why use k2cr2o7 , kcl h2so4 in uv calibration ?,why use benzophenone & caffene acetone in hplc calibration ?,what is leading peak in hplc ?why we do the calibration of limit of stry light in hplc & uv ?

3723


Why are use silicon oil mr?

1256


How require to perform linearity as per ANVISA? What are the acceptance criteria?

1399


Why dissolution test is not performed in all of the products

2577


what is impurity profile. how to interpret this impurity profile to a drug product or drug substance.

2678


for which product require to do content uniformity? what is limit of cu?

867


We use Potassium Dichromate solution for the calibration of UV-Visible Spectrophotometer in UV region. My question is to calibrate visible region which solution could be used in photometric accuracy

1962


we can use expired sample for validation and analyst qualification?

860


why salisylic acid not using now days for disdolution calibration?

836


If we have 5 strength which is not dose proportinate and excipients also diffrent in each strength then how we can proceed for Force degradation? and excipient are same but not dose propotinate the how FD?

858


is it nessesary to do solution stability for 7 days?

816


how to set sample and standard concentration in RS method?

964


What is shaking level in GC?

833