Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what are the different methods of analysing related
substances test,what are LOD AND LOQ .HOW TO REPORT
IMPURITIES WHEN LOD AND LOQ LIMITS R SPECIFIED

Answer Posted / ananthan chandrasekar

LOD-Limit of detection.It is the lowest amount of the
analyte that can be detected and not necessary to be
quatitated.

LOQ-Limit of Quantitation. It is the lowest amount of the
analyte that can be detected and quantified.

If u get the impurity value below LOD, impurity result can
be declared as BDL(Below detection limit)

If u get the impurity value morethan LOD value but lessthan
LOQ value,impurity result can be declared as BQL(Below
Quantitation limit)

Only those impurities which are exceeding LOQ value to be
declared as per calculated value and this value canbe
included for Total impurity calculation.
For reference, See the example
Impurity LOD LOQ Calculated value Result
A 0.002% 0.006 % 0.001% BDL
B 0.002% 0.006 % 0.003% BQL
C 0.002% 0.006 % 0.008% 0.008%
D 0.002% 0.006 % 0.009% 0.009%
Total impurity = 0.008% +0.009 % =0.017%

Is This Answer Correct ?    58 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

In Assy by potentio metry titration method how select MET U ,DET U, SET U,

2245


how to select short coloum and long coloumn for new molecule

2527


what is impurity profile. how to interpret this impurity profile to a drug product or drug substance.

2682


calibrtion procedue of LC-MS

2761


if instrument calibration fails then what require to do?

1020


How to establish relative response factor for hplc. Why it is required?

1270


in dissolution if one bowl got 70 percent 2nd bowl got 80 percent and 3rd bowl got 90 percent then how proceed?

809


why xterra column require to use at higher ph?

972


What is dose dumping? why require to do?

1048


how decide the clining method and cleaning method validation require for this perticular products?

822


what is mean by peak intigrity?

1027


In rs method development when we are going area normalization method to dilute standard method?

1567




2392


Why we check moisture,ash & AIA in product

1943


for which product require to do content uniformity? what is limit of cu?

877