Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the Column Endcaping in HPLC ?

Answer Posted / rajkumar

In columns Stationary phase is Organic phase is coated over
the Silica surface. But during manufacturing it is not
possiable that all active sites(Silica surface)are coated
with organic phase there will be some vacant areas. In that
areas it is possiable to coat with Long chain Organic phase.
so small chain such CH3 is coated in that areas.

Is This Answer Correct ?    17 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is delay volume?

1391


Home heating oil or furnace oil what is made from? Can (base oil plus diesel/kerosen) = home heating oil?

2182


Ratio of Water and Acetonitrile(diluent) is not recommended to use in cleaning method validation,why?

2962


How we can identify process related and degradation impurity in single method with short period?

812


why we should take dst factor for below 1%moisture samples

2666


what is the structure of DOWEX-50

5517


Difference between the quantitative analysis and qualitative analysis?

1175


what is lod and loq ?,why use k2cr2o7 , kcl h2so4 in uv calibration ?,why use benzophenone & caffene acetone in hplc calibration ?,what is leading peak in hplc ?why we do the calibration of limit of stry light in hplc & uv ?

3666


why are measure gas flow " ml " in Gas chromatography

1659


sop of a uv visible spectrophotometer double beam elico model

5920


in sampling of raw material which side is pasted sampled labels

1832


what is impurity profile. how to interpret this impurity profile to a drug product or drug substance.

2629


USP methodology, EP methodology, IP methodology, among three if possible to use one methodology for qualify working standard to use USP, EP, IP ? Please explain...

2011


What is the accrptance criteria in RSD for RS method precision on basis of impurity percentages?

821


[3/30, 13:29] Manoj P Venkatpurwar: How hplc column selection according to structure? How mobile phase buffer selection on molecule structure?

785