Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why deutiriated chloroform used in NMR for sample
prepration. what reaction takes place.give reasons

Answer Posted / vani

1)deutirIUM will not give nmr signal.
2)Here proton exchange reaction takes place b/w the
chloroform(CHCl3)and the analyte protons.If deutirated
chloroform ie CDCl3 is used, it is easy to locate the
position of proton in the analyte which is exchanged with
the D in the
deutirated chloroform.

Is This Answer Correct ?    11 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

in hplc chromatogram started from left to right and in uv spectrum started from left to right

889


if tech transfer fails whay require to do?

771


why glutent are detected in the rice cereal baby food product even manufacturer claimed that they are using rice and milk only?we have using ELISA to do the test,and rice supposed not containing any glutent,rite?We already repeat the test so many times and it still detected.just wondering where the glutent came from?

2706


why should we perform dissolution PVT calibration only by UV spectrometer, not by HPLC ?

1642


what are the standard methods for HPLC?

2734


what is the extinction coefficient for Indomethacin or at 319nm wave length.

3990


please explian me about area normalisation method,diluted standard method,impurity vs impurity and which one has to be selected in method development

1574


In GC calibration,what is the procedure to calibrate the TCD (thermal counductivity detector)suggest ?

3119


is it nessesary to do solution stability for 7 days?

718


In performance Check of GC Why Hexadecane Peak is Considered 

2986


Tell me something about Vitamin A test method by HPLC

2627


Why only Copper standard is used to calibrate Atomic Absorption spectrophotometer?

2668


How you develop a method in HPLC?

2561


why we should take dst factor for below 1%moisture samples

2612


Is it nessesary all multimedia dissolution require descriminatory?

739