Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the difference of use of LOD test and Karl Fischer
titra.?

Answer Posted / ram.ch

In LOD test both organic solvents and water content are
determined.
& in karl fisher titration only water content is determined.

Is This Answer Correct ?    13 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

give clarity of linearity and range in method validation

2426


what is different when impergnated silica plates are used in separation of azo dyes using column chromatography?

2037


How to choose the which salt is suitable for mobilephase

3266


How to set specification of assay, fisdolution and related substances?

888


How to calibration of the uv spectroscopy and its test?

1204


what is mean by covalidation

788


effect of pore size, pore volume, partical size, column length, carbon load on retention time? what is carbon load? what is the use?

938


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1608


Why dissolution test is not performed in all of the products

2543


if you have given a blank water how you analyse by general analytical techniques?

2040


How to set analyticl specification for combination products?

756


why multimedia dissolution require to do?

843


Difference between hlaf and rlaf

2121


Difference between the quantitative analysis and qualitative analysis?

1192


Which type of column should i use to check the purity of high molecular weight protein using HPLC reverse phase column chromatography? Hi everyone. I wanna to check the purity of high molecular weight protein (collagen) with MW of ~130 kDa using a HPLC. I know C18

1926