Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the diff betwen calibration and system suitability?

Answer Posted / bhushan

Calibration is only performance check for instrument, where
as System Suitability is the criteria in which we look for
various parameters like analyst, reagents, system for a
particular analysis

Is This Answer Correct ?    6 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

In which situation we require to prepare the standard solution from sample in Related substance method?

785


in which situation ion pair require to use?

825


Which parameters require to do in tech transfer?

762


Why we check moisture,ash & AIA in product

1889


How can we confirm the HPLC column is end-capped or not? Is it possible to identify by physical appearance?

3222


in dissolution why pool sample needed? in which type of drug pool sample need?

3182


analytical method validation require to with respect to release specification or shelf life specification?

800


why salisylic acid not using now days for disdolution calibration?

779


why octanol used to determine the partition coefficient ?

2459


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1603


all types of questions asked at the cipla interview

4687


[3/30, 13:29] Manoj P Venkatpurwar: How hplc column selection according to structure? How mobile phase buffer selection on molecule structure?

804


How do we fix the sample concentaryion in hplc method development. What is the basis?

1211


why cone formation during dissolution?

792


what is definition of validation? which components are followed give detail?

2379