Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What should be the precision for HPLC during technology
transfer?

Answer Posted / basha

6 times of system suitability will be considered as system
precission.6 times of different assaying is method
precission

Is This Answer Correct ?    2 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is %labelled amount in content uniformity of dosage unit and its calculation?

5215


we are performed SOR for a particular product the limit is -6 to -10.We face particular bathes it is not meeting the specification.we performed diffrent instrument diffrent analyst we are getting diffrent diffrent results.solvent is dimethyl sulfoxide what could be the reasion

1866


what is mean by ambient temperature?

912


How to know the estimated LOQ concentration in ppm

1206


Why only hydroxy naphthol blue indicator is used for standardisation of 0.05M EDTA solution instead of solochrome Black T or Euriochrome Black T indicator which is used for all sample analysis with 0.05M EDTA solution?

2715


How to compare XRD graphs against standard and carry polymorpism study of API's by powder XRD method?

3860


What is the principle of Thermal conductivity detector and FID?

2724


For standardization of volumetric solutions, acceptance limit for concentration is considered as 10% of nominal concentration and %RSD as NMT 0.2% (for appropriate no. of replicates). But , if %RSD has not met, what should be further action?

1903


if identification threshold crosses the limits then what next step?

854


why does used dry caffien in HPLC calibration?

2026


What is diffrence between extractable volume and deliverable volume? Answer pls

4562


in which situation require to use paddle and basket?

731


for which product require to do content uniformity? what is limit of cu?

811


if peak get problamatic then what require to do?

794


In GC calibration,what is the procedure to calibrate the TCD (thermal counductivity detector)suggest ?

3170