Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is method development parameter in HPLC method
development

Answer Posted / ramana

Parameters involved during initial stage of Analytical
Method development:

1. Solubility
2. Pka Value
3. Selection of Buffers
4. pH of buffer/mobile phase
5. Composition of Mobile Phase
6. Selection of Column
7. Optimization of Analyte signal
8. Objectives of Seperation
8.1 Analysis time
8.2 Resolution
8.3 k factor (Capacity factor)
8.4 Peak height
8.5 Asyymetry
8.6 Theoritical Plates
9. Flow rate

Is This Answer Correct ?    54 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to set analytical specification for combination products?

771


How to fix the sample conc. in Related substances test by HPLC?

1026


1)What's the meaning of Absorption,give a example. 2)What's the meaning of Adsorption,give a example. 2)what is the difference between Absorption and Adsorption.

2828


How do we fix the sample concentaryion in hplc method development. What is the basis?

1137


Related substance method equivalency on control sample or spiked sample?

711


How much is the standard area for glc analysis

2209


Why dissolution test is not performed in all of the products

2481


for heavy metal test lead used in which form pure form or any other form for preparation of lead standard sol

5989


How to set specification of assay, fisdolution and related substances?

820


Colorimtry

1617


If change in specification which parameter require to do for validation? if change in chromtographic condition then which parameter? if api change then which parameter? if change composition then which parameter? if old method not work out then whicj parameter? if additional one impurity added then which parameter of validation require to do on above each conditions? elaborate separately

795


What is the difference between Discriminating media and DPDM(Dissolution Profile with Different Media)

7472


What is the difference between purge septum flow and column flow in gas chromatography?

2478


AT WHAT CONDITIONS WILL YOU ANALYSE A SAMPLE,WHICH ARE PRESERVED AT OTHER THAN THE AMBIENT CONDITIONS?(ie COLD STORAGE SAMPLES BELOW 20* CENTIGRADE?

2012


what is diffrence between specificity and selecivity?

713