Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is specificity?

Answer Posted / m

In Specificity Study we proves that our method of analysis
is Specific for drug subsatnces/product or intrest of peak
by resolving and proving that no interfearance observed at
retention time of known impurity and main peak due to
unknown impurity and matrix component.

Is This Answer Correct ?    34 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

in api coa contains only process impurities and in product coa contains degradation impurities?

733


what parameters we will consider while developing a HPLC method and how we confirm our HPLC method is valid?

3750


How to know the estimated LOQ concentration in ppm

1277


what is lod and loq ?,why use k2cr2o7 , kcl h2so4 in uv calibration ?,why use benzophenone & caffene acetone in hplc calibration ?,what is leading peak in hplc ?why we do the calibration of limit of stry light in hplc & uv ?

3724


how much mass should be there in volumetric flask while in preparation of sample for assay? 

2664


why cone formation during dissolution?

847


We use hicrome 10 cxs column in hplc analysis....pls tell me.. what is the meaning of 10 cxs?

1784


why we should take dst factor for below 1%moisture samples

2716


on the basis of bcs class how to proceed the solubility?

831


what is the extinction coefficient for Indomethacin or at 319nm wave length.

4125


Why we select scan range from higer wavelength to lower wavelength in uv visible spectroscopy and ftir spectroscopy ? .

982


What is the difference between Discriminating media and DPDM(Dissolution Profile with Different Media)

7604


if your product is soluble in 0.1n hcl and water then which you choose as media from these 2 media?

735


Why only Copper standard is used to calibrate Atomic Absorption spectrophotometer?

2785


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1653