Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why is the rating of transformer done in kva and not in kw.

Answer Posted / thiyagarajan

kv is an apparent power kw is an active power the ratio
between active and apparent power is power factor ,we dont
know the power factor before connecting to load that why we
are used to refer kv in transmission

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why electronic instruments is more favorable than electrical?

1974


I have a current transformer with 1 main reading meter with transformer outside the building and a control panel having 5 CT reading meters with black round coils inside the building. I want to know, A) when current pass through the Transformers, will the current be reduced or be the same and after that B) when current pass through the CT meters with black round coils, will the current be reduced or be the same. C) in the above process will the reading of the main meter be same or different, from the total reading of all the 5 CT meters.

1820


how to calculate the settings for shaft ct protn in hydro generators

1969


In our plant we have installed new MCC with ELR and CBCT which is detecting some leakage current in the system but it leading to some confusion when to check that in which feeder which is drawing current we put off the whole panel itself but still CBCT detecting some leakage current so can anybody ans me , where i am going wrong or how to detect whether its actual leakage or CBCT malfunctioning.

2261


Why we used 690V in ACS 800 drives.Why dont use standard voltage like 415v or 1.1Kv

2456


What are the three major categories of error?

1227


WHY THREE PHESE SYSTEM VOLTAGE APPLIED IN 440 VOLT

2346


how much GROUND & NEUTRAL VOLT maintain in data center.

2058


HOW TO CALCULATE THE HEAT AND LOAD OF LT-SUBSTATION WHICH CONTAINS 2*1MVA TRANSFORMERS,LT SWITCH BOARD,MLDB,ACB,BUSBAR,ETC...?

3947


how to copy from plc ge fanuc versamax series,all input and output, adress, and printout.

2503


why should the primary of transformer be connected in delta in a heat run test?

1986


What is earth system using on the floater TN-S or TT. Iam not sure and what ICCP

1733


how many load we can take for lighting

2284


1600kva capacity Transformers how the bucholz relay,Oil temperature,winding,surge relay relays setting are to be done

1908


For RCD (Residual current device) Icu is defined. How i can find Ics for them?

2066