What is the power factor you maintain at ur organization?
Answer Posted / shasheen
In our orgn we are maintaining 0.98 by APFC at L.T side
and H.T Capacitors parallel to motors and H.T bus
capacitors. If our power factor is less than 0.95 in A.P
State elect board will impose fine Our running load is
35 MVA OF Cement Plant
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
Why does inductive loads consume KVARs?
Fantio of tranformer
Is it possible to protect 3phase overload and earth fault of the 3phase system using two CT's.
What is class ab operation?
Name two low frequency oscillators?
how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating
Hi, Next week Iam appearing RRB exam for section engineer. So help me to get modal question papers for this position. Iam very thankful to you. Whether question will be fully techanical format or general form. Please give me a details regarding this exam.
I have a current transformer with 1 main reading meter with transformer outside the building and a control panel having 5 CT reading meters with black round coils inside the building. I want to know, A) when current pass through the Transformers, will the current be reduced or be the same and after that B) when current pass through the CT meters with black round coils, will the current be reduced or be the same. C) in the above process will the reading of the main meter be same or different, from the total reading of all the 5 CT meters.
how to find impedance , mutual indatnce in transmission lines
what are the dimensions for 200 kva transformer plinth (plateform),in which pcc m20 is used..
explain the process of commutation in a dc machine. Explain what are inter-poles and why they are required in a dc machine.
Purpose of providing neutral isolation panel for parallel operation of diesel generator
In a power conditoining unit (inverter) of a solar plant when we measure the d.c. current fed by different strings of solar plates to inverter, the current in the negative wire is less almost by 1 ampere to the current in its positive wire say current in positive wire 5 A , then current in negative wire of the same string is 4 A. Since the current entering should be equal to current leaving then why the current is noticably less in negative wire.
what is EIB lighting control system? what is the advantages of this system?
What happen if we apply square wave or traiangular waveform voltage to the transformer primary winding instead of sinusoidal wave?