Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why we wre doing linearity siudiec in hplc method validation

Answer Posted / k.praveen kumar macleods pharm

If the method is linear or not from certain range suppose
in assay validation the range is 50% to 150% we are
injecting minimum 6 levels and also Calculate the regration
line the correlation coefficient should be less than 0.999
Here regration line equation is y=mx+c

where y = Regration line
m = Slope
c = Intercept.

and also calculate residual sum of squares from theorical
and practical

Is This Answer Correct ?    13 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

in which situation require to take incident in validation?

1778


Describe your field experience sample type collected,sample techniques,field measurements taken and equipment used?

2742


which situation gc hs and gc als require to use?

838


in hplc chromatogram started from left to right and in uv spectrum started from left to right

1015


how many types of balance calibration test?

2353


acceptance criteria for lod & loq by standard deviation of response and slope??

2639


if you get peak in blank then what require to do?

1018


how you start RS method development when for new product?

775


identification is for unknown? qualification for known? reporting for LOQ?

775


Please give idea about method development for cleaning method and how maco level establish

790


What is the difference between spectro meter and spectro photo meter?

11614


how a particular wavelength can be different for a particular compund while analysing by uv and by HPLC.

2360


[3/28, 20:52] Manoj P Venkatpurwar: how many impurities require to inject in assay specificity that how we can find out? and in Rs also how?

844


how to selecet an exact coloumn for an new molecule development by hplc how to select exact salt as buffer for new molecule development by hplc what is the the process to select the mode of saparation of compoundes by hplc what is the use of ph of buffer what is use of buffer,ph,organic phase,ans methods how the molecules get saparated in coloumn,

2649


for inorganic molecules require to do RS, Assay and disso?

774