Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why we wre doing linearity siudiec in hplc method validation

Answer Posted / k.praveen kumar macleods pharm

If the method is linear or not from certain range suppose
in assay validation the range is 50% to 150% we are
injecting minimum 6 levels and also Calculate the regration
line the correlation coefficient should be less than 0.999
Here regration line equation is y=mx+c

where y = Regration line
m = Slope
c = Intercept.

and also calculate residual sum of squares from theorical
and practical

Is This Answer Correct ?    13 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Identify problem faced when mass spectroscopy is used with HPLC system ?

1878


process of Diclofenac sodium,IP.

2219


how decide the clining method and cleaning method validation require for this perticular products?

766


What is the acceptance criteria for moisture balance when calibrated with sodium sulfate

2045


Why do we use KMnO4 in the test of control of obsorbance ? and why do we take specific quantity i.e 57-63mg?

2833


how will you do the prep for unstable componds?

2030


AT WHAT CONDITIONS WILL YOU ANALYSE A SAMPLE,WHICH ARE PRESERVED AT OTHER THAN THE AMBIENT CONDITIONS?(ie COLD STORAGE SAMPLES BELOW 20* CENTIGRADE?

2061


why require to do water content for drug product?

835


if you get peak in blank then what require to do?

979


2. Two grams of Benzoic acid are dissolved in 200 ml of water and extracted with 200 ml of diethyl ether. The distribution coefficient of benzoic acid is 100, and its dissociation constant is 6.5 10-5. Calculate the distribution ratio (D) of benzoic acid at pH 2, 5, and 6. 3. Calculate D at pH 2 to 10 (1 unit apart) in the above problem, and plot D versus pH.

2224


Describe your field experience sample type collected,sample techniques,field measurements taken and equipment used?

2709


in hplc chromatogram started from left to right and in uv spectrum started from left to right

953


how you start the solubility study?

835


Why dissolution test is not performed in all of the products

2537


Why irmoisture balance is used for corrugated box moisture testing

2404