Questions / { aniket s kadam }
Questions Answers Category Views Company eMail

The company where I am working, their is rosemount 5400 series radar type level transmitter, it is meant to show level of filled tank, but along with the level it is showing temperature also, so my question is how a onon-contact type radar type level transmitter can show temperature even if it does not have any contact with the fluid?

Process Control Technologies,

Instrumentation 1835

If a normal magnetic type flow transmitter that can measure flow, temperature and show this parameters on field, is it possible by any means to get this (flow and temperature) parameters info. On dcs? And if yes then with HART, FO communication or any other communication system?

Process Control Technologies,

1 Instrumentation 1831

If a flow transmitter (magnetic type FT) that can measure flow and temperature, then why in some industries people use flow transmitter and temperature transmitter in the same line 1 after another? Even after 1 single flow FT is capable of measuring flow as well as temperature.

Process Control Technologies,

1 Instrumentation 3961

I have installed a RTD whose length is 2250mm(RTD stem length), but it's upper 200 -250mm is out of the reactor, and this upper 200mm stem is surrounded by atmospheric temp. And the lower portion i.e. 2000mm is in contact with the measuring fluid, then does the final measuring temp. Gonna change as the upper 200mm RTD stem is out of reactor?

Process Control Technologies,

1 Instrumentation 2015

How does a single acting, spring return ball valve actually work? Does it require continuous air supply? 

Process Control Technologies,

Instrumentation 1653

In a ball valve which require 24v dc supply to operate, whose solenoid valve doesn't have any + or - indication, how can we make wiring connectionto solenoid valve?

Process Control Technologies,

1 Instrumentation 3510

What is the difference between conductive lined pipe and conductive unlined pipe? Why do we see that?

Process Control Technologies,

Instrumentation 2619

Why does a pressure gauge installed on reactor, doesn't have any vent line below to release the pressure? Is it any kind of designing mistake or it actually does not require any vent line? And if it does not require any vent line below it then how we are gonna release the pressure built inside the pressure gauge?

Process Control Technologies,

Instrumentation 1712

Is it ok, to use non-contact type Radar type LT, on a tank that is half circular from the bottom side? If yes the, isn't the waves gonna bent in other directions? 

Process Control Technologies,

Instrumentation 1711

What is shielding effect?

Process Control Technologies,

Instrumentation 1750


Why is the length of cable layyed from RTD to temp. Transmitter should be minimum? Why does heating effect takes place in their?

Process Control Technologies,

1 Instrumentation 5427

Why do we use triad cable for RTD to Temp.transmitter connection? Why we don't use 3 core cable?

Process Control Technologies,

1 Instrumentation 13762

What are continuances of connecting earthing and shield of branch cables (instrument to Junction box), at the same earthing pot provided on JB? Is it ok, or may produce some problem? 

Process Control Technologies,

Instrumentation 2011

Why do we have earthing cable in branch cable and shield in the same cable?

Process Control Technologies,

Instrumentation 2141


 [1]   2    Next