Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Un-Answered Questions { Engineering }

What is I to C?

2164


Write a shell script to delete all files present in a directory “dir1”. Any error, if it occurs while carrying out this operation should be stored in a file errorlog

2136


What are test values for an 63 KVA and 100 Kva Distribution Transformers for the following typical tests 1)Magnetic balance 2)Short circuit test 3)Open Circuit test 4)Vector group confirmation test .please give me the standard values for all the above tests.

2728


I have Completed my diploma in Electronics in year 2009.I got low score in TOEFL.SO what should i do to get the visa...I am confident that I will get the visa..But probable chances for getting visa....and i also got I20 and paid Visa interview fees.....

2053


can anyone can let me know in Eurotron Micro cal 2+ calibrator in milli amps source mode we are not able to get 20 milli amps output it only produces 1.52 milli amps out, but display shows increase in milli amps , and err6 displays, let me know how to remove the err 6.

2277


Terminal blocks is used for segregate the connections... There is any principle for terminal block..?

2142


what is physical distance of isolator to VCB in 33/11kv sub stations

2149


what kn of disc is used in 33kv,132kv,220kv,400kv,800kv transmission line

3294


i want use the cable size 16cx4 core aluminium usege watts 240x2000w this cable size is correct?

2211


what are the values of VRY,VYB,VBR,Vry,Vyb,Vbr,Vrn,Vyn,Vbn for Magenetic balance test of 100 KVA and 63 KVA Distribution transformer

2985


what exactly commisioning work does in electrical site work... LT side?..

1957


What are the causes for the failures of sandwich type (Al) busducts?

1874


Which Class insulation is prefered for the sandwich Busducts ? Why?

2044


How should I begin a conversation that I need a change in the job to a known person in his organisation?

1881


how to calulate short circuit current for the following: 1.cable connecting 11KV of 22KV/11KV transformer to 11Kv of 11KV/415V transformer 2.what cable size should i use.

2166