Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


why
we
have
to
use
only
900
ml
buffer
in
dissolution
apparatus ?
what
are
the
conditions
that
favours
the
selection
of
volume
of
buffer?



why we have to use only 900 ml buffer in dissolution apparatus ? what are..

Answer / t reddy

selecting volume of buffer depends upon the sink condition of the drug...

example: if ur drug maximum doasge is 500mg means.. take 3times of these dosage that is 1500mg... dissolve it 500ml buffer, there should not be any formation of precipitation in buffer... if there is any prcptn means increase the buffer volume until the drug getting completely dissolved... that will be the final volume for ur dissolution studies.

there is also another way 1st know the maximum solubility of dosage

example:if 500mg(consider this as 100%) in 900ml of buffer is the maximum solubility of the drug... then your doasge should not be more than 350mg(70%) in 900ml of buffer. u can use any dosage form less than 350mg for 900ml of buffer

Is This Answer Correct ?    6 Yes 0 No

Post New Answer

More Health Pharma AllOther Interview Questions

Hi Sir?Mam, If i complete SAS CLINICAL in India, can i step forward to USA for job trials? How far is it possible? Am a B.pharm student ,willing to make up my Master's degree too,will this both M.Pharm and SAS help me out to get a job in USA? Please help me out with a good answer.

0 Answers  


What do you mean by GTT? What are the effect of GTT on film coating.

0 Answers  


Why 3 validation  batches charge in stability ?is there any specific reason for 3 ?

1 Answers   Torrent Pharma,


What interests you about the position of Medical Librarian in our company?

0 Answers  


Tolerance limit for dissolution media rpm sampling point.

1 Answers   Torrent Pharma,


Why SLS used as dissolution medium

0 Answers  


Give an example of how you've handled a problem patient.

0 Answers  


How can I assign a retest date for solvents e.g. toluene, methanol, etc?

0 Answers  


plz.mail me model papers of drug inspector of chhattisgarh..or MP.if Posible. Mail Id-recha_1428@rediffmail.com...mrs_1428@rediffmail.com,

0 Answers  


WHAT IS MEANING OF DEAIATION WITH EXAMPLE

0 Answers   KarMic,


Tell us about a situation in which you took the extra step for a patient.

0 Answers   Claris Lifesciences,


difference between RF and correction factor?

0 Answers   Torrent Pharma,


Categories