Using test data as part of a comprehensive test of program
controls in a continuous online manner is called a/an:
A. test data/deck.
B. base case system evaluation.
C. integrated test facility (ITF).
D. parallel simulation.
Answer / guest
Answer: B
Base case system evaluation uses test data sets developed as
part of comprehensive testing programs. It is used to verify
correct systems operations before acceptance, as well as
periodic validation. Test data/deck simulates transactions
through real programs. An ITF creates fictitious files in
the database with test transactions processed simultaneously
with live input. Parallel simulation is the production of
data processed using computer programs that simulate
application program logic.
| Is This Answer Correct ? | 4 Yes | 0 No |
The PRIMARY reason for separating the test and development environments is to: A. restrict access to systems under test. B. segregate user and development staff. C. control the stability of the test environment. D. secure access to systems under development.
An IS auditor performing an access controls review should be LEAST concerned if: A. audit trails were not enabled. B. programmers have access to the live environment. C. group logons are being used for critical functions. D. the same user can initiate transactions and also change related parameters.
An IS auditor should be able to identify and evaluate various types of risks and their potential effects. Which of the following risks is associated with authorized program exits (trap doors)? A. Inherent B. Detection C. Audit D. Error
Which of the following functions is performed by a virtual private network (VPN)? A. Hiding information from sniffers on the net B. Enforcing security policies C. Detecting misuse or mistakes D. Regulating access
Which of the following is the BEST audit procedure to determine if a firewall is configured in compliance with an organization's security policy? A. Review the parameter settings B. Interview the firewall administrator C. Review the actual procedures D. Review the device's log file for recent attacks
When performing a general controls review, an IS auditor checks the relative location of the computer room inside the building. What potential threat is the IS auditor trying to identify? A. Social engineering B. Windstorm C. Earthquake D. Flooding
Which of the following would an IS auditor consider to be the MOST important when evaluating an organization's IS strategy? That it: A. has been approved by line management. B. does not vary from the IS department's preliminary budget. C. complies with procurement procedures. D. supports the business objectives of the organization.
Which of the following BEST describes the role of a systems analyst? A. Defines corporate databases B. Designs systems based on the needs of the user C. Schedules computer resources D. Tests and evaluates programmer and optimization tools
In a risk-based audit approach an IS auditor should FIRST complete a/an: A. inherent risk assessment. B. control risk assessment. C. test of control assessment. D. substantive test assessment.
The PRIMARY purpose of undertaking a parallel run of a new system is to: A. verify that the system provides required business functionality. B. validate the operation of the new system against its predecessor. C. resolve any errors in the program and file interfaces. D. verify that the system can process the production load.
Which of the following procedures would BEST determine whether adequate recovery/restart procedures exist? A. Reviewing program code B. Reviewing operations documentation C. Turning off the UPS, then the power D. Reviewing program documentation
Various standards have emerged to assist IS organizations in achieving an operational environment that is predictable, measurable and repeatable. The standard that provides the definition of the characteristics and the associated quality evaluation process to be used when specifying the requirements for and evaluating the quality of software products throughout their life cycle is: A. ISO 9001. B. ISO 9002. C. ISO 9126. D. ISO 9003.