Hi Friends i need Electronics&Instrumentation Engg question papers for BARC written test by coming 20th May 2008 pls post ur use full info to kkumarei@gmail.com. Or for suggestions pls give one missed call to 9962122264
1553hi friends,im an instrumentation and contol engg student,can u hlp me of suggsting barc written question paper,my id is roysuvaranjan@gmail.com, cel no.9563591747
16011.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling
1996installation process of orifice,a question asked for confusion creation in interview by BARC 1.if orifice is tightly fitted with pipe ,it will act like venturi 2.if orifice is left hanging in between liquid it will not create the pressure difference exactly,
1703if differential pressure created by orifice falls below vapour pressure of liquid flowing through it what will happen
1 4861Post New BARC Instrumentation Interview Questions
As a business analyst, what tools you think are more helpful?
What is hierarchical database?
Rules for multilateral trade in agricultural products were already in place at the end of the uruguay round. What is the purpose of the agricultural negotiations under the doha round?
In Verilog code what does “timescale 1 ns/ 1 ps” signifies?
How much one have to pay to TV channel and news papers to show their Ads? I know little bit about News Papers, could any one tell about TV channels with example?
Is wordpress.com more secure than wordpress.org?
How is data stored in a database?
What is the difference between the bitcoin blockchain and ethereum blockchain?
What are the different types of array in php?
State the importance of xml- based layouts?
List the various advantages of sap business workflow.?
What is the difference between an electric motor and an electric generator?
Does the system.exception class have any cool features?
What are the assumptions made for kynch theory?
What is sql clause?