Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Company Name Starts with ...
#  A  B  C  D  E   F  G  H  I  J   K  L  M  N  O   P  Q  R  S  T   U  V  W  X  Y  Z

OPS Interview Questions
Questions Answers Views Company eMail

why in three phase 440 circuit in all phase current is almost equal L1-35 A,L2-34 A ,L3-31 A but in nutral when i check with clamp meter it shows 25 A?

4 13411

why for transformer protection we protect tranformer from 3rd hormonics and 5th hormonics and what is the reason of generating these horminics in electrical system?

2 9837

what is difference between start imitation and start interlock for 3 phase motor protection ?

2 8039

how we can adjust for three phase motor cold stall time ,hot stall time and thermal register set up?

2925

why voltage rating not mention at HPSV or HPMV lamps?

2 6905

can we use HPSV LAMP in HPMV LAMP fixture ?and viseversa.

5 13909

Why Transformer Neutral having one earth pit ( more earth electrode resistance) whereas body have many earth pit ( less earth electrode resistance)?

4394

how to calculate restraing current and operating current for differential protection if 20 mva transformer is OLTC 33 kv/11 kv ? and what should be the type and ratio of CT?

2 6149

how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage.

1 4810

how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.

2275

Post New OPS Interview Questions




Un-Answered Questions

Validation rules, what are they use for in salesforce?

491


What is the benefits of microsoft word?

774


Research serves a single purpose-that of providing information to assist marketing manager to make better decisions? Elaborate this statement.

2105


How long does chkdsk last?

1070


what are the difference between AC lamp and DC lamp

2144


What is the difference between html4 and 5?

929


What are the customizing prerequisites for document clearing?

1449


What do you understand by classes in typescript?

194


What is the difference between rest and soap?

1220


What are your future plans for the company if permanently employed?

2223


How to Connect via ODBC using Delphi or C++ Builder ?

1771


How you can use data provisioning in sap hana studio?

89


What are the steps required to render all the xml documents to html on server?

867


How do you register service providers?

719


Can you install wordpress without a domain name?

168