what is diffrence between neutral and earth wire
Answer Posted / anand
Neutral is a return path to complete the electrical
circuit. It is originated from transformer star point.
Earthing is connected to the panel or equipment to protect
the equipment & human life when leakage occurs.
Is This Answer Correct ? | 68 Yes | 4 No |
Post New Answer View All Answers
Is it required to lay 2 runs of GI wires along with armoured cables from one power DB Machines of higher rating?
what is the difference b/w ground & virtual ground?
anyone please send transformer parameter design formulas & details of tap changer ? plz i have interview this week its more helpful for me ?
define the non synchoronism of synchoronous machine in general g or m??
Explain with example of functional requirements of protection relay in terms reliability, selectivity, sensitivity
How to do cable earhing? whether by grounding Armour to ground or by running extra G.I wire along with cable? which one is preferred mostly amoung them? If the second one is more preferable how many GI wires to be run along with cable (1 or 2)?
what is the difference between online & offline caliberation of KWH meters. Can Digital meters be caliberated
circuit diagram of trip circuit supervision relay
FOR 16/20 MVA 132/33 KV ONAN/ONAF TYPE TRANSFORMER IT IS DESIGNED FOR 16 MVA WITH ONAN CONDITION.IT BECOMES 20 MVA UNDER ONAF CONDITION.LOAD LOSS IS GUARANTEED FOR 65KW AT 20 MVA AND % IMPEDANCE 13.75. PLEASE TELL US AT WHAT LOAD LOSS AND % IMPEDANCE IT SHOULD BE DESIGNED FOR 16 MVA AND WHAT WILL BE ITS EFFICIENCY AT 20 MVA?
What is minimum permicible value of leackage current for LT Panle when applying voltage up to 3 KV for 5 Minuits?
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
in a simple IDMT relay we use neutral point of ct for earth fault then what is the requirement of neutral ct and cbct?
What are the transformer losses?
hi I have done 3 yrs diploma in electrical engg after 10+2. I have 16 years of work experience into design proposals sales and engg application development in LV/MV swithcgear and sub station automation field. I want to apply for immigration to new zealand but I am not sure whether I qualify or not since I dont have a degree. Can anyone advice? Thanks Riz
i am electrical and elctronics engg passed out in 2009 want to attend for reliance placements.plz send me apttitude ,technical and hr question answers to my mail plz. my mail id-kat.bindas@gmail.com