The armature of shunt dc motor has 0.8ohm resistance and motor
is to run on 120V circuit.If motor is suddenly thrown on
circuit while armature at standstill then current drawn by
motor will be??Also back emf in normal running is 110V

Answer Posted / shoaib

At stand still back emf Eb=0
Now
V=Eb + Ia Ra
120=0 + Ia(0.8)
Ia=120/0.8
Ia = 150amp

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Is there any Institution for giving M-tech in Electrical engineering for those who r in service? Give the details please.

1576


What is the difference IN MCCB's between thermal magnetic and electronic tripping system ?

1546


in ACB breaker requireding 3200Amps. buscoupler getting OFF mode and again it reset and getting normal position give me a required answer?

1842


What is the reason behind current flow(20 A) in amain earth cable of an SMDB? Is cuurent flow(45A etc) through a neutral cable acceptable?

1508


what is the IS foe lightning arrester?

1688






Why MCCB is Getting tripped sometimes when there is no load in the Midnight ?

1395


what is LSR?

1721


Can we check ELCB constantly from R1 to R8 phase in 1 no DB?

1226


How to measure the Harmonic Distortion of UPS ie THD?

1738


Does all the output contacts (N/O as well as N/C) of a Numerical relay operate when relay receives a binary input/inputs or contacts are designated to specific logic input/inputs and only these contacts operate?

1619


What is your acheivements

1675


what is the formula for efficiency of francis turbine and generator for hydropower? what is best way to select francis turbine and generator?

1996


A motor running with lenze frequiency inverter stops if I REDUCE SPEED with 25% load.If I run it in High speed and medium speed running smoothly with full load.please help me to solve it.

1529


Can anyone provide with a SLD for HT panel installation for a 33KV line and distribution end has three 1.5MV transformers. Is it suitable to use OCB or VCB and also provide me the suitable rating and its connection diagram.

2891


what is mean by kneepoint voltage? when it will happen? ( my doubt is, if CT secondary is open means ct get saturation or blas? what are factors are required for calculations? plz give currect anws:

1529