Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is working principle of ACB and VCB?

Answer Posted / jayprakash gupta

Vcb (vacuum circuit breaker) use of ht site
Acb (Air circuit breaker) use of lt site

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How energy is generated in hydroelectric power plant?

1318


in a solar power plant,we are going to step up the voltage 350V to 33kv, and to 132kv GSS. i want to ask that if it is possible that 315v/33kv is not possible because we also use 315v/11kv. or it should be 415v/33kv? is it effects generation or losses?  the second question is-generation is depends on LV winding? or LV winding design for generation voltage?

1749


which connection is safer series or parallel?usually which connection we prefer at home?

10036


what is working process of star delta controlling circuit ?

1902


Cables Construction hi friends, 0.6/1/1.2 kV LV , DC and Control cables are concentric copper conductor what does its means and what is the use of concentric copper conductor,and are this with copper tape shield or copper screening, ? thanks

1779


what is the difference between c power and U power acb breaker

6433


What is the difference between solid grounding and impedance grounding?

2131


at work we have a 3 phase motor but on testing one phase isnt getting a reading. it runs 24 hours a day all week. stops and starts well no noise or heating. the phase isnt down to earth.is it just a bad meter reading or not? phases one and three came up with a resistance reading of 0.4 but phase 2 couldnt get anything shows up as open circuit.

1678


actually i can't understand what is 3dB ? and it's really not clear to me.please any one let it me be cleared.

2270


mccb service sittings be done?

1823


In layman terms, what is the difference of Dielectric strength and dielectric constant when speaking of an insulating oil

2723


why generator efficiency is more in swinburnes test?

2219


How to reduce the static electricity producing in solvent room? By P.D.Patil BioCon

2107


what is the correct method for the outdoor termination of 19/33 KV HT cable step by step?

2093


Why collecting electrode of ESP to be earthed

2162