What are Line losses and how can be it minimized/controlled.?
Answer Posted / abc
There typically two types of losses in line T&D.
1. Technical Losses
The technical losses are due to energy dissipated in the conductors, equipment used for transmission line, transformer, subtransmission line and distribution line and magnetic losses in transformers.
Technical losses are normally 22.5%, and directly depend on the network characteristics and the mode of operation.
The major amount of losses in a power system is in primary and secondary distribution lines. While transmission and sub-transmission lines account for only about 30% of the total losses. Therefore the primary and secondary distribution systems must be properly planned to ensure within limits.
The unexpected load increase was reflected in the increase of technical losses above the normal level
Losses are inherent to the distribution of electricity and cannot be eliminated.
There are two Type of Technical Losses.
1. Permanent / Fixed Technical losses
Fixed losses do not vary according to current. These losses take the form of heat and noise and occur as long as a transformer is energized
Between 1/4 and 1/3 of technical losses on distribution networks are fixed losses. Fixed losses on a network can be influenced in the ways set out below
Corona Losses
Leakage Current Losses
Dielectric Losses
Open-circuit Losses
Losses caused by continuous load of measuring elements
Losses caused by continuous load of control elements
2. Variable Technical losses
Variable losses vary with the amount of electricity distributed and are, more precisely, proportional to the square of the current. Consequently, a 1% increase in current leads to an increase in losses of more than 1%.
Between 2/3 and 3/4 of technical (or physical) losses on distribution networks are variable Losses.
By increasing the cross sectional area of lines and cables for a given load, losses will fall. This leads to a direct trade-off between cost of losses and cost of capital expenditure. It has been suggested that optimal average utilization rate on a distribution network that considers the cost of losses in its design could be as low as 30 per cent.
Joule losses in lines in each voltage level
Impedance losses
Losses caused by contact resistance.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What are the applications of autotransformers?
how did the testing of protection relays done through current injection
what kinds of Transformer oil grade is better for power transformer ?
what is the relation between knowing of the distance between power transformer and the capacitor feeder in case of parallel operation
How to calculate the volumetric capacity of a oxygen & Nitrogen gas Cylinder if pressure is 145 kg/cm2 & water capacity of cylinder is 67 liters.
If 100 KAV USP dedicated earth got disconnect / Cut. What will happen at load.
Thumb rule of cable size(rm>30 rm)X multiplying factor=ampere
How to derive detailed design of Suitable bus Bar for 100A for 6.6KV?
What is the source of dependent source ?
how we can calculate 2 phase welding transformer rating or total power?
why we get 2 differnet values for power factor in 2 watt meter method in 3 phase
What will be the effect if I use inverter as UPS mood?
What is a advantage of Self Reset Lockout ? On Fault breaker get trip & fault no longer exist then self reset lockout how inform us?
HOW WE CHOOSE EARTH'S POTENTIAL AS ZERO V?
What is Harmonics how it is produced and what is the method to control the same