What are Line losses and how can be it minimized/controlled.?

Answer Posted / abc

There typically two types of losses in line T&D.

1. Technical Losses

The technical losses are due to energy dissipated in the conductors, equipment used for transmission line, transformer, subtransmission line and distribution line and magnetic losses in transformers.

Technical losses are normally 22.5%, and directly depend on the network characteristics and the mode of operation.

The major amount of losses in a power system is in primary and secondary distribution lines. While transmission and sub-transmission lines account for only about 30% of the total losses. Therefore the primary and secondary distribution systems must be properly planned to ensure within limits.

The unexpected load increase was reflected in the increase of technical losses above the normal level
Losses are inherent to the distribution of electricity and cannot be eliminated.
There are two Type of Technical Losses.


1. Permanent / Fixed Technical losses

Fixed losses do not vary according to current. These losses take the form of heat and noise and occur as long as a transformer is energized
Between 1/4 and 1/3 of technical losses on distribution networks are fixed losses. Fixed losses on a network can be influenced in the ways set out below
Corona Losses
Leakage Current Losses
Dielectric Losses
Open-circuit Losses
Losses caused by continuous load of measuring elements
Losses caused by continuous load of control elements

2. Variable Technical losses

Variable losses vary with the amount of electricity distributed and are, more precisely, proportional to the square of the current. Consequently, a 1% increase in current leads to an increase in losses of more than 1%.

Between 2/3 and 3/4 of technical (or physical) losses on distribution networks are variable Losses.
By increasing the cross sectional area of lines and cables for a given load, losses will fall. This leads to a direct trade-off between cost of losses and cost of capital expenditure. It has been suggested that optimal average utilization rate on a distribution network that considers the cost of losses in its design could be as low as 30 per cent.
Joule losses in lines in each voltage level
Impedance losses
Losses caused by contact resistance.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

we are having 15kw and 3kw motor both can run in same time , instead of using copper we are using ug aluminium cable , 35 sq.mm is suitable for its current carrying capacity..?

1318


What is minimum phase system?

663


why tertiary winding is used in transformer with diagram?

1780


What is the function of RCBO? What are the different sensitivity ratings & each application?

2139


If anyone would like to know or practice for FEWA papers contact me on mohamedrashad2@hotmail.com Just completed the supervisor exam in April 2021

723






how to design step down 12 V, 1mA small transformer from 220 V AC? Because according to VI relation and power transfer it results bulky...

1669


how the synchronizing is obtained at bus couplers in grid substation? (because there we cannot change the frequency in one of transmission lines like in generator synchronization)

1849


what is the reason for indication of light in the earth lamps of main switchboard.if there is an earth why does one lamp get dim and the other two bright.

1872


what is the sludge current

1562


In MEP Services what are parts of STP and what are there function?

2935


Can i replace Earth leakage relay to the faulty Earth Faulty Relay

1041


An 8 pole, 50 Hz, 3-phase IM is loaded to a poing where pull out torque will occur. The rotor resistance per phase is 0.3 ohm and motor stalls at 650 rpm. The rotor reactance at stand still is A 2 ohm B 1.25 ohm C 3.15 ohm D 2.25 ohm

1753


I want to know all basics of electrical engineering

1431


hello if any one have papers vof hpcl or sail, plz send me

1425


how to calculate the settings for shaft ct protn in hydro generators

1500