How will you change the action of a control valve?
Answer Posted / morsli
you have in positionner the direct and reverse action ,you have only to commutate to direct action means when the signal fron the controller rise the out put of the positionner will rise also ,in same direction 4-20 ma signal to i/p positionner the signal will be 3-15 psi from the positionner..
but in reverse action when the signel from the controller increase the out put of positionner decrease reverse action 4-20 ma signal to i/p positionner the signal will be 15-3 psi from the positionner.
sincerly
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Coal mill Instruments Equipments for cement plant And process diagram ?
How r the calculation of process line mpm.
what is effect of specific gravity in differential level transmitter , explain formula related with this .
Instrumentation symbols interpration, P& ID, Logic diagram analysis, Electrical drawing analysis.
What care will you take in the installation of control valves,SCADA,DCS and FOC in Oil and Gas Project?
how will you check torque value during Factory acceptance Test for control valve/ESD ON/OFF VALE how will you confirm this torque value is being correct, Which document will you be refer.
what is the difference between attemperator and desuperheater ?
Sir , i have completed my M.Sc In Instrumentation and presently working in Maintenance department 3 yrs Exp , is there is any possible for work in offshore ..
How a conductivity sensor & analyzer work at boiler, whats the principle & science is beyond this,How conductivity sensor sence & convert signal & move toward analyzer & analyzer show reading in percent? also what is temperature compensate option in conductivity analyzer
How will you test a transistor with a multimeter?
A flange is used for instrument connection for a system with a design temperature of 316C (600F) and a design pressure of 1000 kPa (145 psi). What is the class rating of the flange to be used for this application? Explain your answer
Please can anybody help for control valve sizing step by step procedure?
why direct mounted pressure transmitters is always installed with DBB ( double bleed block) valve in process line or top of the tanks ?
Specify eight technical requirements that you would consider important, when deciding upon a particular control valve?
i am from instrument branch i want paper patern of mahagenco . any pevious years paper regarding my branch send me please . please.....