what is the advantage and disadvantage of billing in kwh
and kvah by electricity board .
Answer Posted / julio trujillo, pe
I thank Maurits Paath for the info on Malta, I didn't know they adopted the KVAh unit and now 2 countries are ahead on power metering.
It's interesting that we still refer as "poor PF" or "harmonics problem" when talking about load characteristics. We must change these perceptions, specially when metering is involved. These were problems when meters couldn't read them; as we already have meters that register KVAh then we can bill the whole energy use.
Of course, there's still an infrastructure issue because harmonics produce heat, vibration, and "noise". Also, large reactive loads produce power leakage towards earth. These must be dealt with, and billing for them will provide funding.
There's another issue; researching I found that meter companies have not reached a uniform method for KVA calculation or a direct means of measurment. Thus, there will be different readings between meter brands. Although the difference shouldn't be large, a standard should be established, and this will happen when demand for the product increases.
So, actual metering losses is solved with KVAh register adoption. Demand for these meters will push for a standard establishment. And new profits, along with client's request for lower bills, will provide for better infrastructure. This is progress.
Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
What is called grain-oriented laminations?
-What should be minimum value of insulation resistance and maximum value of earth resistance at any electrical instillation and what is method of testing the same.
Define conversion efficiency of a power amplifier.
What is the function of under voltage release ?
WHY CBCT USE ONLY IN Y PHASE NOT OTHER PHASES
WHY IS THE EARTH FAULT CURRENT ALWAYS LESS THAN THE NORMAL CURRENT??
Which motor is 3.3 or 11kV more reliable, in terms of efficeancy,maintenance, reliability.
A 230V dc shunt wound motor has an armature resistance of 0,15Ω.When operating on no load at 650 rev/min the armature current is 6A . The motor takes a full load current of 85A. Calculate the full load speed if the field flux is (i) maintained constant (ii)reduced by 0,03
hai now i am working as a electrical design engineer in construction field can i get a job in oil and gass field or power plant project as a electrical design engineer?
How many methods use the load flow solution?
How earthing of switchgear system to be done.
i want bhel placement paper for electrical if anybody having pl send to my id kavitha867@myway.com immediately
What is the formula to calculate the rating of a three phase air circuit breaker
What is making & breaking current ???
Explain the operation carried out in thermal power stations?