Answer Posted / ashmal zadir
RCD is the group name for residual current protective devices.
RCCB is an RCD that fits in the breaker panel
RCBO has additional overload protection and also fits in the breaker panel. RCBOs were mainly designed to protect individual circuits inplace of an MCB. RCCB is used to protect many circuits with individual MCBs
I assume RCB is just another name for RCD. Here is a good link where i found the information.
http://www.cycloflow.com/2014/02/what-are-elcb-rccb-rcbo-and-rcds.html
| Is This Answer Correct ? | 8 Yes | 0 No |
Post New Answer View All Answers
What we mean by vintage of an engine+Generator?
What will happen if i replace a inductive proximity switch with photo sensor in a machine?
What is the effect of interchanging core(made of steel) and winding(made of copper) material in case of transformer? Give proper explanation in regard to different losses in transformer.
sir, iam a electrical engg graduate and i want to go in automation sector and for this i have decided to do industrial training for this,plz suggest me some good institute for the same in delhi,ncr. my degree percentage is 58%, can i get job after doing training, plz help....
1) why a dg set shows variation of power factor and load when synchronised with other dgs? 2)Why the load sharing is not become equal in all dgs?. 3)When a dg set will not run on auto start?
what is servo motor and how it works?
what is the minimum winding resistance of 30hp compressor, to run or to switch on
Difference between Earthing Truck & Earthing trolly for HT panel
How to know th details about an electrical Drawing ? Please mention the easy method.
what are the reasons of CT circuit faulty in busbar protection scheme?
is all the servo motors having brake?please specify which servo motors having brake for stop on position and which are not.
i am an maintenance engineer. one distribution board have 5 feeder. recently its ELR trips frequently, but it take some times after trip( 10min,20min..)but 3 feeder no load. two feeder only loaded. i checked one feeder IR value all values are above 50Mohm.but B phase to Earth is only 9Mohm.any problem about low value
In Power Line Communication (PLC) the wave trap is used to block communication signals from entering neighboring lines. My question is this: Why do they allow for different filtering arrangements on these wave traps? Isn't it always going to be a low pass filter since we want the power frequency to go through, and the comm signal blocked?
what are the stresses in circuit breakers ?
How you give clearance to a spare feeder.