What is the difference between Split ring and slip ring?
Answer Posted / shahzaib/zeeshan
split ring is mirror like shape. while slip ring is circle like shape. split ring is used in d.c motor for reversing the direction of current after each half revolution. on the other hand slip ring is used to keep the direction of current in same senses
| Is This Answer Correct ? | 2 Yes | 3 No |
Post New Answer View All Answers
which mm cable should be used for 1.hp immersible pump motor for the distance of 330 metres?
give me a clear defination of inductance,and how can u calculate inductance of a motor
how to measure the transformer resistance values(dyn11)?and howmuch the minimum value?
Given a collection of points P in the plane, a 1-set is a point in P that can be separated from the rest by a line; i.e. the point lies on one side of the line while the others lie on the other side. The number of 1-sets of P is denoted by n1(P). The maximum value of n1(P) over all configurations P of 19 points in the plane is 18
sir my exam is on 19/6/2013 under electrical branch pls send me sample aptitude questions as well as sample technical questions for jindal steel and power company
What is the unit audit? if our Max demand is something and we found much more unit then how to improve our max demand?
FOR 16/20 MVA 132/33 KV ONAN/ONAF TYPE TRANSFORMER IT IS DESIGNED FOR 16 MVA WITH ONAN CONDITION.IT BECOMES 20 MVA UNDER ONAF CONDITION.LOAD LOSS IS GUARANTEED FOR 65KW AT 20 MVA AND % IMPEDANCE 13.75. PLEASE TELL US AT WHAT LOAD LOSS AND % IMPEDANCE IT SHOULD BE DESIGNED FOR 16 MVA AND WHAT WILL BE ITS EFFICIENCY AT 20 MVA?
Can you tell me more about pu systems (per unit systems )calculation in large power systems? how to get the base for voltage and power in generator, transformator and transmission lines?
What is the permissible limit of shaft voltage for 6.6 KV motors ? Why? Is there any standard is available?
An 8 pole, 50 Hz, 3-phase IM is loaded to a poing where pull out torque will occur. The rotor resistance per phase is 0.3 ohm and motor stalls at 650 rpm. The rotor reactance at stand still is A 2 ohm B 1.25 ohm C 3.15 ohm D 2.25 ohm
what do w do when the output of generator is fluctuating?
what is the effect of connecting three phase supply lines to three phase auto transformer output terminals through a fuse of 10Amp and a circuit breaker (MCB). Is this connection permanently destroy the transformer?
Formulae for calculating the transmission line losses for different voltage levels
how to design coil turns ?
How to select HT/MV cable size ?