what is the meaning of Ring Mean Unit in a substation or
trasformer also tell me its oerpuse?

Answer Posted / hesham

RMU IS used to feed the transformer from two different feeders within ring
1- TRM ( two incomer and one outgoing feeding only one transformer 2+1 )
Or ( 1+2 ) one incomer and two outgoing feeding two S/S.

2- QRM ( 2+2 ) two incomer and two outgoing feeding two transformer
or ( 1+3 ) one incomer and three outgoing feeding three s/s.

Is This Answer Correct ?    19 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Whether the vacuum contactor requires Short circuit protection?If No,why?

1581


Is there any standard guidelines/Criteria to design NGR/NGT.?

2365


What is the difference between line drop and percentage line drop?

1075


what is formula to cal cute earth pit numbers and size of earth strip used in earthing?

1796


How cable from Kit-Kat to main switch, from starter to motor are designed?

1578






in conventional fan regulators how the current varies with speed?

1441


A 3 phase transformer's (Y-Y) Y and B phase is (Y and B connection not broken) broken from neutral and R and Nutral connection is ok, what will be the relay tripping and why

1480


which type of questions asking for solar companies?

1125


In 90 kva alternator that produce the output voltage is 115(p-n),200(p-p) at 1500 rpms means what ampere it produced ?

1601


if there are six generators (3 gas CATT, one Jenbacher o1 MW each, and two nos Diesel 01 no 01 mw other 0.65mw EDGs ( say), 3 CAtt gas set have identical pole pitch,01mw EDG and Jenbacher gas Set have different pole pitch, how their power connection can be done to connect a common bus bar during installation. in short, how different pole pitched generators power connection can be done to connect a common busbar system through generators incomer ACBs.

1134


What is George phenomena to start the synchronus machine?

3645


In EHV transmission line a neutral grounding reactor is often placed at neutral point of shunt reactors. What is the recommended protection for this neutral grounding reactor? Should I use a fast closing switch to bypass neutral grounding reactor when this protection operates?

2755


why servomotor motor? where i apply for best output?

1552


How many lightning arrestors to be installed on 50MX60MX10M building and is there any formular for that?

1473


What is the working principle of CFL & T5 tube light & 40W tube light with electronic ballast?

3496