What is the use of conservater, bucchos relay, breather in
a transformer?
Answer Posted / rajput deepak
# 6 Bucholz relay is the protective deivce which protect
the
transfomer from overload,overheat,short ckt protection.
when ever any over load or short ckt happen ,the first
thing increase which is temp of transfomr and this relay is
connected with temp sensor controller and these realy has 2
NO contact first alarm contact and another is tripping
contact.
breather as name indicate ,when the temp of oil get
increasing it expand and Dry air of conservator tank goes
out,after cooling the oil ,again conservator tank need Dry
air ,which is supplied by breather and silica gel takes out
the moisture from this air.
conservator tank is stored the cools oil.
Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
In EDO ACBs what is a purpose of closing coil and motor, what is the operation of these devices are they inetconnected. means if we give supply to motor and by BCS we charge Closing coil,what exact is operation is and how it charge a spring of ACB. Sir if anybody has an wiring diagram please send me the link to operate and EDO breaker.
what is the defination of Cable database? What are the points are considered while preparing cable database? Is there any sample available for cable database?
how a.c. genarator control power factor when its conected to grid supply by incrising or decresing excitation voltage.
what is rating boiler
Draw a SLD of HT distribution EB grid up to users Transformer?
1.what is the difference between transformer differential and busbar differential.2)why we are using 2 slope for trafo diif and 1 slope for busbar diff.3)what is the purpose of metrosil and stabilizing resistor in high impedance relay circuit.4)how metrosil reduce the peak volage.5)what is the funtion of stabilizing resistor
What is rotating magnetic field?Discuss elaborately.
What are the operation carried out in thermal power station?
WHAT IS THE TECHNICAL SPECIFICATION OF C CURVE & D CURVE LEGRAND MAKE MCB
A cotter joint is generally used to transmit
L.A. (Lightening Arrester) is located at a place from where transmission line enters the transmitting substation. So L.A. (Lightening Arrester) is the first equipments which has to encounter with lightening, high voltage surges and switching surges. It has to absorb energy of lightening, high voltage surges, and switching surges. L.A. (Lightening Arrester) is made up of layers of semiconductors. If these layers can not tolerate energy released by lightening, high voltage surges, and switching surges the L.A. (Lightening Arrester) blasts.
we have a lot of model of rectifier but thyristor rectifier is the most rectifier that use in power system. Do you know why this rectifier is used?
List examples of voltage source?
which pump used in WTP explain the function of VFD how to dtermine capacitorbank of capacity one plant
hi plz send me reliance placement papers..i.e electrical technical papers that have been asked in reliance test.