i/p converter always for supply pessure from 3~15 psi
only !! And from where this converter bleed the air.

Answer Posted / vinoth

I/P converter gets the bleed off air from the Air compressor
unit.
From air compressor unit, air will go to a regulator
from where the Pneumatic air is supplied to the I/P converters.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

i have done DAE in Instrumentation and Process Control. i have applied for an apprentice training in chemical company after three day my interview will be conduct but i need more information about industrial process control and controller. my e mail is imran_dilsetu@yahoo.com please tell me interview question relative to instrumentation ?

1872


key phaser where is use and work

1458


What is Droop? What is Step/Gradient Limiter in Turbine Governor control?

2921


How to calibration coriolis flow meter?

1293


what is the usage of QDV & VOLUME BOOSTER

1772






If i have 4 Allen Bradely make RS logix 5000 PLC and for viewing that we are using 4 RS view SCADA for 4 different packages. Now, I will want to view two packages on only one SCADA. Then how i will do it?

1830


What are primary elements of measuring pressure? Which type of pressure can be measured by these elements?

637


Why even multiple power supplu r used in instrumentation system?

4157


A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?

875


WHAT IS MEANT BY PROJECT MANAGEMENT STRATEGIES IN INSTRUMENTATION?

3034


Explain the difference between mmwc and mmwg?

3521


where proximity sensor installed on tank in loading arm application

1524


Give Detail information about plc,dcs,and scada system?

1266


How to calibrate an pressure gauge with yantrika test bench?

2371


Can I route 110 VDC and 24 VDC in a same Duct for our Interposing relay cabinet? IF yes or NO Please provide me IEEE Std. for the same. Please i required it on Urgent basis, i need to design IRP Cabinets and we have MCC 110VDC and Our Coil side is 24VDC, Please help as soon as possible.

1785