Why is it that polarization index type test is required for
MV and HV motors and not for LV motors?

Answer Posted / prashant

because the moror windig is balance or not and winding of the motor is open or not

Is This Answer Correct ?    0 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

USE OF 8 WAY PAN ASSEMBLY

1500


we have a lot of model of rectifier but thyristor rectifier is the most rectifier that use in power system. Do you know why this rectifier is used?

1331


What is the function of auadag in a cro?

684


How to calculate the Efficiency of Chiller

2858


Is Transol transformer oil comparable to nynas nytro libra?

2631






what is the need to express current and voltage in rms value? rms value is also called as effective value,what is effective value?

1488


Define cut-off rate?

656


what are the factors to be considered while design the breaker either HT or LT??

1411


what is meant by 3rd hormonics ?

1490


How many Zones can be in Conventional type fire alarm system & how can we detect the fire in Conv. type FAS?

1381


why we use two slope(differential & restraining) in differential relay.but in busbar protection differential we are using only one slope?please explain

1735


Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1.  H1-H2 = H2-H3 H3-H1 2.  H2-H3 = H3-H1 H1-H2 3.  H3-H1 = H1-H2 H2-H3 For the LV side also: 4.  X1-X0 = X2-X0 X3-X0 5.  X2-X0 = X3-X0 X1-X0 6.  X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0  H2-H0  H3-H0    X0-X1  X0-X2  X0-X3 128.0  119.9  7.2      29.2   13.3   15.8 70.7   128.4  59.2     23.4   22.0   3.6 7.2    120.1  128.1    13.4   29.3   15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?

1370


how to extend relay operating timing in 24V dc relay card (without using Timer )

1467


what happen when power factor of 2 parallely operated transformer become equle?

1716


What is magneto on a gas generator. how it functions. its out put is d.c or a.c. how it can be checked for correct functioning

1511