i want use pressure transmitter for flow ,how?

Answer Posted / sudarsun

Differential Pressure transducer along with a Venturi pipe
should do the work. The pressure at the normal diameter vs
the pressure at the shorter diameter should be proportional
to the rate at which the fluid flows.

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How d.p. Transmitter can be applied to open tank?

638


is motorized valve closed when power shutoff?

1160


types of cable..? Use of every types of cable..?

1597


what is the usage of QDV & VOLUME BOOSTER

1772


plz send me general of ongc

1536






flow transmitter formula?

2357


What is PDS and PDMS ?

1693


How to control flow variations in magnetic flow maters..... When i will provide proper earthing?

1793


What is compensation for flow ? Why we use compensation ? What are the factors of different compensation ? We not use then what problems may happen ?

1475


With N nodes and B branches what will have a network ???

1522


what is the vital subject for scoring bhel exam&what is the question pattern

1876


How is flow measured in square root?

674


Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =

1442


why orfice is not used for main steam flow calculation

1601


Drum level tx with GP4 with zero elevation:7300mmh20 on HP and 8050mmh2o on LP as range but on commissioning the tx readiing is max,Why this reading?

1489