Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why high Voltages come in multiple of 11, like 11 KV, 33KV,
66 KV, 132 KV etc.

Answer Posted / vinjam sasikumar

rms value = form factor * avg value
basically thee value of form factor is 1.11
so the ratings are in multiples of 11 kv
When the capacity increases, this is not true. It becomes 800kva, 1000kva

Is This Answer Correct ?    0 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

please explain how to do 'pole drop test' on generator?

2919


What is kirchoff ’s current law (kcl)?

1109


How PSV sizing being done

2337


What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side

1472


what is the importance of earthing system on the generators big capacity and small?

1806


What is nichols chart?

1339


PLZ EXPLAIN CORONA,SKIN,BIRD PALE,SPAN,SAG Effects of power cable.

2037


give single line diagram of D.G distribution form alternator to main L.T panel?

7571


What is the current carrying capacity of 35sq.mm flexible cable?

1466


how you configure motorvision relay (L&T make)from DCS

4908


what is the pulse and audio frequency transformer? what is different between induction regulators and tap changing transformer?

2126


Mr. mohh sahid m not satisfied for ur answer to the que weather the size of transformer increases or decreases withchange in fr for more detail go to the answer given by me

2143


what is self capacitance of inductor

2439


Why the earth to phase voltage is high 250 compare to other two phases

1526


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?