Why high Voltages come in multiple of 11, like 11 KV, 33KV,
66 KV, 132 KV etc.
Answer Posted / vinjam sasikumar
rms value = form factor * avg value
basically thee value of form factor is 1.11
so the ratings are in multiples of 11 kv
When the capacity increases, this is not true. It becomes 800kva, 1000kva
| Is This Answer Correct ? | 0 Yes | 3 No |
Post New Answer View All Answers
please explain how to do 'pole drop test' on generator?
What is kirchoff ’s current law (kcl)?
How PSV sizing being done
What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side
what is the importance of earthing system on the generators big capacity and small?
What is nichols chart?
PLZ EXPLAIN CORONA,SKIN,BIRD PALE,SPAN,SAG Effects of power cable.
give single line diagram of D.G distribution form alternator to main L.T panel?
What is the current carrying capacity of 35sq.mm flexible cable?
how you configure motorvision relay (L&T make)from DCS
what is the pulse and audio frequency transformer? what is different between induction regulators and tap changing transformer?
Mr. mohh sahid m not satisfied for ur answer to the que weather the size of transformer increases or decreases withchange in fr for more detail go to the answer given by me
what is self capacitance of inductor
Why the earth to phase voltage is high 250 compare to other two phases
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?