Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why is starter necessary for a three-phase induction motor?

Answer Posted / subhakanta sahu

As we know at the time of starting an induction motor the rotor is stand still hence the slip is 1.if slip is 1 the rotor induced voltage is maximum hence drives maximum current in the rotor circuit.This rotor current current has impact on stator current(As per LENZ's law).This is the reason why an induction motor takes high current at starting(About 5 to 7 times the full load current).

This high current causes voltage fluctuation,unwanted power loss & unwanted stress to the system or equipment.So it has to be reduced by using different starting methods.

There are two possible ways to limit the starting current
1.Reduce the applied voltage.
2.Increase the rotor resistance.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

i have interview in Pepsi company what type of question will ask please send the question and answeer

3487


how to calculate distance between busbar supporters for LT panel, what are the factors influencing in this design

5334


What type interview questions ask in Electrical technicians

1813


How to justify this statement ??? "Capacitors in series provide less capacitance but higher voltage breakdown rating for the combination"

1889


how oltc works in rectiformers of higher rating (27 mva,200v dc,120kamps) please provide me full information with diaggram.

2151


could an induction motor be used for regenerative braking in electric-train control? in this type of application would some scheme have to be devised to obtain low synchronous speeds while braking? would induction-motor drive, therefore, be suitable for passenger service?

2042


plz tel me syllabus and exam date 4 jr executive engg (electrical)

1992


I meggared my 2c*70 sq mm AL AR XLPE cable. its one end show 50 M ohm . is my cable is safe for laying. I have only one phase and neutral.

1896


What is the automatic voltage regulator with servomotor?

2050


Why r u using pf panel. what the uses

2016


What is the rating of a circuit breaker needed for 300 kv load in 33KV supply line of 33/415 transformer ? Whether 800/1200 amp vaccum circuit breaker can perform for a 33 KV line in input in 415 volt in output of the transformer ?

1675


Approach of a cooling tower is the difference between temperatures of what factors?

1165


what is the effect of earth on capacitance in 3-phase and 1- phase transmission line?

2376


What are safety device in vcb and acb?

3901


when measure the core loss of three phase distribution transformer or three phase reactor loss, one phase shown negative watt loss. why??

1989