Answer Posted / parthipan
copper losses depends on current and iron losses depends on
voltage. Total transformer loss depends on volt-ampere (VA)
and not on phase angle between voltage and current i.e., it
is independent of load power factor. That is why
transformer's rating is in KVA
Is This Answer Correct ? | 5 Yes | 0 No |
Post New Answer View All Answers
what is the function of gss in the dg set.
I had applied for JE in PSEB, Can you pls send me the Question bank for related to my field
How we can defined theecopper cable size if we know the aluminium cable size?
Why back emf used for a dc motor? Highlight its significance.
L.A. (Lightening Arrester) is located at a place from where transmission line enters the transmitting substation. So L.A. (Lightening Arrester) is the first equipments which has to encounter with lightening, high voltage surges and switching surges. It has to absorb energy of lightening, high voltage surges, and switching surges. L.A. (Lightening Arrester) is made up of layers of semiconductors. If these layers can not tolerate energy released by lightening, high voltage surges, and switching surges the L.A. (Lightening Arrester) blasts.
I have 440v power coming to facility,( not being used ) can I buy large generator, (gas) to sell power back to electrical co.
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
What are the various types of BUSBAR Schemes? explain each
I am shobana from Chennai. I am having my personal interview on 19th Dec at Chennai.kindly mail me the questions to mail id shobana.shanthi@gmail.com
what is meant by loss of field in a DC motor? how a universal motor works?
can we use CBCT in neutral of solidly grounded transformer? in place of three phases we can pass only one phase which decreases the size of CBCT?
What will be the effect if I use inverter as UPS mood?
How can i calculate the Breaking capacity of molded case circuit breaker, is the breaking capacity of CB for Diesel generator shall be less than grid supply's breaker ?
Why in metering Ct for ammeters ct secondary side is grounded for each Ct but not in case of CBCT (Core balance current transformer)..kindly some1 highlights the reason..is it because net flux is zero?
what are the advantages and disadvantages of oil filled cables over XLPE cables